Leayo's integrated solution provides server cabinets, integrated cabinets and modular computer rooms, and other solutions; the characteristics of the solution are: factory prefabrication, fast on-site splicing, plug and play, fast deployment and payment; monitoring system of All critical equipment and Working status, unified monitoring system monitoring and management, can be managed through the device touch screen and remote computer, which is convenient for management. On-demand configuration can save equipment room investment and reduce costs: high efficiency, energy saving, green and environmental protection. Ensure the normal operation of the system to the greatest extent and high availability.
H series cabinet is a multi-functional cabinet, providing 600mm/800mm * 1100mm/1200mm * 2000mm/2200mm (width x depth x height) models, which are widely used in computer data and network systems and are applicable to many industries such as banking, securities, transportation and education. The mechanical, chemical, electrical and other performance indicators of the materials and devices used are in line with national standards, communication industry standards, and relevant standards of EC. Unique geometric design, advanced cable management solutions, can be installed in the cabinet equipment and provide it with a high-quality safe and stable operating environment, and can be equipped with a full range of matching cabinet accessories and cable management accessories, the cabinet can adapt to a variety of field environments. The front and rear doors of the cabinet are equipped with special heat dissipation channels and meet the compatibility of other IT equipment, making it more convenient for comprehensive wiring and management.
The H series 19-inch standard cabinet is adopted. The front door of the cabinet is a single-opening airtight glass door, and the back door is a single-opening sealed metal door; it is equipped with an emergency ventilation system and has an exhaust function. The cabinet size is 600*1200*2000mm (width*depth*height); 3-60kVA UPS and 3.5KW-12.5KW precision air conditioners are available, and the system has a 10-inch touchscreen monitoring system, which can Monitor the UPS system, refrigeration system, power distribution system, temperature and humidity inside the cabinet, and the status of the front and rear doors in the cabinet, and SMS alarm function (option). Configure the front and rear lighting of the cabinet, two-color colorful lights, two temperature and humidity sensors, and one smoke detector as a whole; configure water immersion according to the number of air conditioners.
19-inch rack-type structure, mainly used in integrated cabinets, can be directly installed in the cabinet; dual power supply switching function (optional) can be configured, with anti-surge protection function; integrated power distribution function: with UPS input and output, Bypass control function, with over-current protection function, to ensure the safety of power consumption, with real-time load current display, with output control and over-current protection function, to reduce the impact of back-end short-circuit faults on UPS; B-level standards, for Each cabinet, has a mains PDU output and a UPS PDU output, and with the redundancy of the refrigeration system, the safety level of the integrated cabinet reaches the B-level standard.
The single-row modular computer room integrates server cabinets, cold aisles, UPS, power distribution cabinets, inter-column air conditioners, and monitoring systems. Server cabinets, UPSs, power distribution cabinets, and inter-row air conditioners form a row. Therefore, the side of the cold aisle without cabinets needs to be equipped with cabinet baffles. Now the single-row modular computer room is gradually replaced by a multi-cabinet integrated cabinet
Server cabinets, cold aisles, UPS, power distribution cabinets, inter-column air conditioners, and monitoring systems are integrated into the double-row modular computer room. Server cabinets, UPS, power distribution cabinets, and inter-column air conditioners cross to form two rows, and a cold aisle is formed between the two rows. Now the double-row modular computer room has gradually become the mainstream of the market, and the traditional decentralized computer room architecture is gradually replaced by the double-row modular computer room.